Partial discharge characteristics of inverter-fed motor coil samples under ac and surge voltage conditions
Author :
Hayakawa, Naoki ; Okubo, Hitoshi
Author_Institution :
Dept. of Electr. Eng. & Comput. Sci., Nagoya Univ., Japan
Volume :
21
Issue :
1
fYear :
2005
Firstpage :
5
Lastpage :
10
Abstract :
This work investigates the partial discharge (PD) characteristics of twisted pair samples for inverter-fed motor coil under ac and surge voltage conditions. It also discusses the difference in the PD inception characteristics of a twisted pair under 60-Hz voltage and surge voltages with a steep wave front. The PDIV under ac voltage was measured and was found to agree well with the theoretical value using electric field analysis and Paschen´s law. The PDIV under surge voltage was measured for different repetition rates and the PDIV for 60-pps repetition was found to be lower than those for 6 pps and for the single shot, which suggested that the electrical insulation performance would be influenced by the repetition rate. The PDIV under surge voltages was 1.5 to 1.8 and 2.3 to 2.7 times higher than those under AC voltage application for the used and virgin samples, respectively.
Keywords :
coils; electric fields; electric motors; invertors; partial discharges; surges; ac voltage; electric field analysis; inception voltage; inverter-fed motor coil; partial discharge characteristics; periodic surge voltage; surge voltage conditions; twisted pair samples; AC motors; Breakdown voltage; Coatings; Dielectric constant; Dielectrics and electrical insulation; Inverters; Partial discharges; Stress; Surges; Wires;
fLanguage :
English
Journal_Title :
Electrical Insulation Magazine, IEEE
Publisher :
ieee
ISSN :
0883-7554
Type :
jour
DOI :
10.1109/MEI.2005.1389265
Filename :
1389265
Link To Document :
بازگشت