• DocumentCode
    1226102
  • Title

    Ruggedized alpha radiation detector

  • Author

    McElhaney, S.A. ; Chiles, M.M. ; Lauf, R.J. ; Bauer, M.L.

  • Author_Institution
    Oak Ridge Nat. Lab., TN, USA
  • Volume
    36
  • Issue
    1
  • fYear
    1989
  • fDate
    2/1/1989 12:00:00 AM
  • Firstpage
    1172
  • Lastpage
    1175
  • Abstract
    An effort was made to develop an alpha-radiation scintillation detector with an entrance window more rugged than that of conventional types. A novel technique for micromachining thin silicon windows has been implemented. Optically clear epoxy is used to couple the scintillator material to a glass light pipe and to give support to thin portions of the silicon window. Tests indicate that overall efficiency is comparable to that obtained with conventional Mylar window detectors. Compared to conventional scintillation detectors, the more rugged alpha-radiation detector is better suited to harsh environments encountered in outdoor surveys, as the silicon window assembly is a solid construction highly resistant to scratches, punctures, water and thermal shock
  • Keywords
    scintillation counters; Si window; efficiency; entrance window; rugged alpha radiation detector; scintillation detector; Glass; Micromachining; Optical coupling; Optical materials; Radiation detectors; Scintillation counters; Silicon; Solid scintillation detectors; Testing; Windows;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.34626
  • Filename