Abstract :
Most of the recently revised safety limits worldwide are set in terms of the limits of rates of internal energy deposition [specific absorption rates (SARs)] for radio/microwave frequencies. Since procedures to ascertain compliance with the SAR limits are cumbersome, requiring complex computer modeling or bulky, mostly homogenous experimental phantoms, they are ignored in favor of easy-to-measure incident fields. Radio-frequency (RF)/microwave installations are thus erroneously declared safety compliant or not based solely on the measured incident fields. A rapid "real-time" SAR determination system is also needed to define the safety zone for RF/microwave installations such as wireless base stations. We describe an approach where the measured incident electric (E) fields (both vertical and horizontal components) for an imaginary vertical plane of dimension 0.96×2.28 m in the immediate vicinity of the intended location of the human may be used to obtain whole-body-average and peak 1- or 10-g SARs using a portable PC in less than one minute of compute time. The method relies on describing the measured E fields in terms of space harmonic components and using the prestored solutions for the internal E-fields (Ex,Ey,Ez) for the various voxels of the human body model for six to ten strongest harmonic components. This approach has been validated using examples of commercial base-station antennas both at 835 and 1900 MHz, elevated or not, for varying distances (1-10 m) of the human model from such antennas. The whole-body-average and peak 1-g SARs are less than 5-10% different than those obtained using the computationally intensive full finite-difference time-domain (FDTD) simulations.
Keywords :
UHF antennas; biological effects of fields; biological effects of microwaves; biomedical measurement; computational electromagnetics; dosimetry; electric field measurement; electromagnetic wave absorption; harmonic analysis; health hazards; medical computing; microcomputer applications; radio equipment; safety; 1 to 10 m; 1900 MHz; 835 MHz; FDTD simulations; SAR limits; bulky experimental phantoms; computer modeling; dosimetry; finite-difference time-domain simulations; homogenous experimental phantoms; horizontal components; human body model voxels; imaginary vertical plane; incident fields; internal E-fields; internal energy deposition rates; measured E fields; measured incident electric fields; measured incident fields; on-site dosimetry system; peak SAR; portable PC; radio/microwave frequencies; real-time SAR determination system; safety assessment; space harmonic components; spatial harmonic components; vertical components; whole-body-average SAR; wireless base stations; worldwide safety limits; Base stations; Biological system modeling; Dosimetry; Finite difference methods; Humans; Imaging phantoms; Microwave frequencies; Radio frequency; Safety; Time domain analysis;
fLanguage :
English
Journal_Title :
Antennas and Propagation, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-926X
Type :
jour
DOI :
10.1109/TAP.2003.809061
Filename :
1208546
Link To Document :
بازگشت