• DocumentCode
    1229433
  • Title

    Error analysis in improved motor control center method for stem thrust estimation of motor-operated valves in nuclear power plants

  • Author

    Jung, Jae-Cheon ; Seong, Poong-Hyun

  • Author_Institution
    Dept. of Nucl. & Quantum Eng., Korea Adv. Inst. of Sci. & Technol., Taejon, South Korea
  • Volume
    50
  • Issue
    3
  • fYear
    2003
  • fDate
    6/1/2003 12:00:00 AM
  • Firstpage
    735
  • Lastpage
    740
  • Abstract
    An error analysis for improved motor control center (MCC) method that estimates the stem thrust of motor-operated valve (MOV) is suggested in this work. This method focuses on providing an alternative means for the periodic performance verification test with relatively lower error than the conventional MCC-based method. For evaluating the overall error of the improved MCC method, the errors are classified into two categories: the biased error and the random error. The biased error consists of the mean of the relative error between measured and estimated torque and that of the stem factor. The random error comes from the statistical analysis of the measured torque, stem factor, and motor electric data. The experiment result shows that this method has a reasonably lower error than the MCC-based method. Therefore, this method can be applied to the periodic verification test of valves with relatively low margins.
  • Keywords
    error analysis; fission reactor cooling; fission reactor materials; nuclear engineering computing; random processes; valves; error analysis; improved motor control center method; motor-operated valves; nuclear power plants; random error; stem thrust estimation; Actuators; Degradation; Error analysis; Motor drives; Power generation; Statistical analysis; Testing; Torque measurement; Valves; Voltage;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2003.812458
  • Filename
    1208566