• DocumentCode
    1229523
  • Title

    Measurement Systems for Dual Range Rocket Motor Performance and LITVC Evaluation

  • Author

    Stone, L.E.

  • Author_Institution
    Aerojet-General Corporation Sacramento, California
  • Volume
    2
  • Issue
    2
  • fYear
    1964
  • fDate
    4/1/1964 12:00:00 AM
  • Firstpage
    431
  • Lastpage
    439
  • Abstract
    Analysis results and relative merits of five measurement system techniques and transducer designs are discussed for providing accurate pressure and force definitions during static solid rocket motor firings with dual level ballistic performance or dual gain liquid injection thrust vector control (LITVC). The accuracy and reliability of each system depends upon the inherent capability and procedures maintained in each approach, the operational levels, and the specific applications; therefore, these factors are necessarily discussed in the text. An analysis of the described force and pressure measurement systems show how an instrumentation measurement system total error may vary from ±0.5% to ±10% depending on the emphasis placed upon the overall measurement system design, and the control exercised during use.
  • Keywords
    Force measurement; Gain measurement; Machine vector control; Maintenance; Performance analysis; Performance gain; Pressure measurement; Rockets; Solids; Transducers;
  • fLanguage
    English
  • Journal_Title
    Aerospace, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0536-1516
  • Type

    jour

  • DOI
    10.1109/TA.1964.4319620
  • Filename
    4319620