• DocumentCode
    1229961
  • Title

    Cascade-Connected Attenuators

  • Author

    Beatty, R.W.

  • Author_Institution
    Central Radio Propagation Laboratory, National Bureau of Standards, Washington, D.C.
  • Volume
    38
  • Issue
    10
  • fYear
    1950
  • Firstpage
    1190
  • Lastpage
    1190
  • Abstract
    Two or more calibrated attenuators are often connected in series (cascade) in order to obtain a desired reduction in power level. The total attenuation of the combination is usually obtained by adding the attenuation of each unit. In general, this will not give the correct result because of reflections due to mismatch at the attenuator junctions. It is shown how the correct value of attenuation can be obtained in terms of reflection coefficient measurements at the attenuator junctions. A nomogram of mismatch error for two cascade-connected attenuators is given.
  • Keywords
    Attenuation measurement; Attenuators; Impedance matching; Network address translation; Radio propagation; Reflection; Voltage;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IRE
  • Publisher
    ieee
  • ISSN
    0096-8390
  • Type

    jour

  • DOI
    10.1109/JRPROC.1950.233427
  • Filename
    1701112