DocumentCode :
1230030
Title :
Measurement of the Electrical Characteristics of Quartz Crystal Units by Use of a Bridged-Tee Network
Author :
Rothauge, Charles H. ; Hamburger, Ferdinand, Jr.
Author_Institution :
U. S. Naval Postgraduate School, Annapolis, Md.
Volume :
38
Issue :
10
fYear :
1950
Firstpage :
1213
Lastpage :
1216
Abstract :
A bridged-tee null network has been used to measure the equivalent resistance and the equivalent reactance of a quartz crystal plate. This measuring circuit has the advantages that shielding is relatively simple (both the source and the detector have a common grounded terminal) and that corrections for all stray capacitances that affect the measurements may be included in the calibrations of the capacitors of the tee. The precision of the measurements is estimated to be 0.3 per cent for the determination of the equivalent reactance and 2.3 per cent for the determination of the equivalent resistance.
Keywords :
Capacitance measurement; Circuit testing; Crystals; Electric resistance; Electric variables; Electric variables measurement; Electrical resistance measurement; Electronic equipment testing; Equivalent circuits; Impedance;
fLanguage :
English
Journal_Title :
Proceedings of the IRE
Publisher :
ieee
ISSN :
0096-8390
Type :
jour
DOI :
10.1109/JRPROC.1950.233757