DocumentCode :
1230091
Title :
Frequency-Stability Performances of the Pulsed Optically Pumped Rubidium Clock: Recent Results and Future Perspectives
Author :
Godone, Aldo ; Levi, Filippo ; Micalizio, Salvatore ; Bertacco, K. Elio ; Calosso, Claudio Eligio
Author_Institution :
Ist. Nazionale di Ricerca Metrologica, Torino
Volume :
56
Issue :
2
fYear :
2007
fDate :
4/1/2007 12:00:00 AM
Firstpage :
378
Lastpage :
382
Abstract :
This paper presents new results obtained with a laboratory prototype of a pulsed optically pumped frequency standard based on a vapor cell containing 87Rb diluted in a buffer gas. A frequency stability of about 1.2 10-12 tau- has been measured, and the value of 3 10-15 for integration times of 105 s has been achieved (drift removed data). These performances show that a suitable implementation of this standard can lead to a compact vapor-cell clock with a very interesting short- and medium-term frequency stability and, consequently, may be of great interest in radio-navigation systems. We also present some possible improvements of the pulsed technique
Keywords :
atomic clocks; frequency stability; frequency standards; rubidium; Rb; frequency stability performances; optical pumping; rubidium clock; shot noise; vapor cell atomic clocks; Atomic beams; Clocks; Frequency; Laser excitation; Masers; Optical buffering; Optical pulses; Optical pumping; Pump lasers; Stability; Frequency stability; optical pumping; shot noise; vapor-cell atomic clocks;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2007.891135
Filename :
4126868
Link To Document :
بازگشت