DocumentCode
1230512
Title
Limits to the Accuracy of 10-V Josephson Standards Revealed by BIPM On-Site Comparisons
Author
Reymann, Dominique ; Solve, Stéphane
Author_Institution
Bur. Int. des Poids et Mesures, Sevres
Volume
56
Issue
2
fYear
2007
fDate
4/1/2007 12:00:00 AM
Firstpage
555
Lastpage
558
Abstract
In September 2004, the Bureau International des Poids et Mesures (BIPM) began a new round of its large-scale international comparison of Josephson array voltage standards with national metrology institutes. As an option, it offers a new simplified measurement procedure, whereby the other participants simply measure the BIPM array as if it were an electronic voltage standard. This presentation discusses the accuracy of JAVS, the problems that were encountered in the new round, and how most of them were resolved
Keywords
Josephson effect; standards; voltage measurement; 10 V; BIPM on-site comparisons; Bureau International des Poids et Mesures; JAVS; Josephson array voltage standards; Josephson standards; accuracy limits; electronic voltage standard; large-scale international comparison; national metrology institutes; Helium; International Committee; Laboratories; Large-scale systems; Measurement standards; Metrology; Object detection; Particle measurements; Uncertainty; Voltage; Accuracy; Josephson arrays; international comparisons; voltage standards;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/TIM.2007.890608
Filename
4126906
Link To Document