Abstract :
By proper design of windings and core, it is possible to operate a linear variable differential transformer with its core in a saturating condition. In this condition, its rectified output voltage is essentially independent of exciting current over a wide range thus avoiding the need for supply voltage regulation in many applications. Design considerations, performance characteristics and a means of reducing the variation of output with supply frequency are discussed.
Keywords :
Circuits; Displacement measurement; Frequency; Instruments; Position measurement; Servomechanisms; Signal generators; Temperature dependence; Transformer cores; Voltage control;