• DocumentCode
    1230544
  • Title

    Use of Saturable Cores in Linear Differential Transformers

  • Author

    Clapp, Charles W.

  • Author_Institution
    Instrument Department General Electric Company Lynn, Massachusetts
  • Volume
    2
  • Issue
    4
  • fYear
    1964
  • Firstpage
    1134
  • Lastpage
    1142
  • Abstract
    By proper design of windings and core, it is possible to operate a linear variable differential transformer with its core in a saturating condition. In this condition, its rectified output voltage is essentially independent of exciting current over a wide range thus avoiding the need for supply voltage regulation in many applications. Design considerations, performance characteristics and a means of reducing the variation of output with supply frequency are discussed.
  • Keywords
    Circuits; Displacement measurement; Frequency; Instruments; Position measurement; Servomechanisms; Signal generators; Temperature dependence; Transformer cores; Voltage control;
  • fLanguage
    English
  • Journal_Title
    Aerospace, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0536-1516
  • Type

    jour

  • DOI
    10.1109/TA.1964.4319732
  • Filename
    4319732