• DocumentCode
    1230586
  • Title

    Compact Wideband High-Current ( ≥ 1000 A) Multistage Current Transformers for Precise Measurements of Current Harmonics

  • Author

    So, Eddy ; Bennett, David

  • Author_Institution
    Inst. for Nat. Meas. Stand., National Res. Council of Canada, Ottawa, Ont.
  • Volume
    56
  • Issue
    2
  • fYear
    2007
  • fDate
    4/1/2007 12:00:00 AM
  • Firstpage
    584
  • Lastpage
    587
  • Abstract
    In this paper, an overview of the development and performance of special compact-and-lightweight wideband high-current multistage current transformers for precise measurements of current harmonics at the National Research Council of Canada is described. These include current transformers with ratios of 1000 A/5 A and higher, with ratio errors of less than 5 10-6 in both magnitude and phase with burdens up to 0.5 Omega and at frequencies up to 5 kHz
  • Keywords
    current transformers; power system harmonics; power system measurement; power transformers; National Research Council of Canada; compact wideband high-current transformers; current harmonics; multistage current transformers; precise measurements; Capacitance; Councils; Current measurement; Current transformers; Dynamic range; Frequency; Magnetic cores; Magnetic shielding; Permeability; Wideband; Compact; current harmonics; current transformer; high current; light weight; multistage; wide dynamic range; wideband;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2007.890802
  • Filename
    4126913