DocumentCode :
1230869
Title :
Influence of Inverter Loads on the Airgap Flux of Aerospace Homopolar Alternators
Author :
Erdelyi, E.A.
Author_Institution :
University of Colorado Boulder, Colorado
Issue :
2
fYear :
1965
fDate :
6/1/1965 12:00:00 AM
Firstpage :
7
Lastpage :
11
Abstract :
In this paper the effects of the time harmonics on the output voltage are investigated. Instead of a complete analysis, the waveshape of the line current is considered as recorded on an oscilloscope when the alternator supplies an inverter. The minimum airgap induction occurs when the magnetomotive forces of the fifth and seventh time harmonic oppose the field excitation. The reduction in the amplitude of the fundamental of the airgap induction caused by the time harmonics was found to be of the order of fifteen to twenty percent for a typical cyclo-inverter load.
Keywords :
Alternators; Frequency conversion; Harmonic analysis; Inverters; Magnetic flux; Oscilloscopes; Rectifiers; Rotors; Shape; Voltage;
fLanguage :
English
Journal_Title :
Aerospace, IEEE Transactions on
Publisher :
ieee
ISSN :
0536-1516
Type :
jour
DOI :
10.1109/TA.1965.4319774
Filename :
4319774
Link To Document :
بازگشت