DocumentCode :
1234675
Title :
Nonconducting polymers on Prussian Blue modified electrodes: improvement of selectivity and stability of the advanced H/sub 2/O/sub 2/ transducer
Author :
Lukachova, Lilia V. ; Kotel´nikova, Elena A. ; D´Ottavi, Daniele ; Shkerin, Egor A. ; Karyakina, Elena E. ; Moscone, Danila ; Palleschi, Giuseppe ; Curulli, Antonella ; Karyakin, Arkady A.
Author_Institution :
Fac. of Chem., M. V. Lomonosov Moscow State Univ., Russia
Volume :
3
Issue :
3
fYear :
2003
fDate :
6/1/2003 12:00:00 AM
Firstpage :
326
Lastpage :
332
Abstract :
An approach to improve the analytical performance of a Prussian Blue (PB)-based hydrogen peroxide transducer is described. In support of this objective, both the stabilizing and anti-interferent properties of nonconducting films were used. Electropolymerization on the top surface of PB modified electrodes is possible due to the high oxidizing ability of Berlin Green, and the growth of nonconductive polymers may be independently monitored by investigating the redox activity of the inorganic polycrystal. The best performance characteristics, which are advantageous over existing H/sub 2/O/sub 2/ sensors, were obtained for PB electrodes covered with electropolymerized o-phenylenediamine (1,2-diaminobenzene). The reported transducer remained at the 100% response state for more than 20 h under continuous flow of 0.1-mM hydrogen peroxide (flow rate 1 mlmin/sup -1/), which improves the stability level among the selective H/sub 2/O/sub 2/ sensors by one order of magnitude. The selectivity factor of the PB-poly (1,2-diaminobenzene) based transducer relative to ascorbate is nominally 600. PB-poly(1,2-diaminobenzene) modified electrode allows the detection hydrogen peroxide in the flow-injection mode down to 10/sup -7/ M with sensitivity of 0.3 AM/sup -1/cm/sup -2/, which is two times lower compared to the uncovered PB-based transducer.
Keywords :
biological techniques; electrochemical sensors; electrodes; polymers; transducers; Berlin Green; H/sub 2/O/sub 2/; Prussian Blue modified electrodes; advanced H/sub 2/O/sub 2/ transducer; anti-interferent properties; ascorbate; electropolymerization; electropolymerized o-phenylenediamine (1,2-diaminobenzene); hydrogen peroxide transducer; inorganic polycrystal; nonconducting films; nonconducting polymers; performance characteristics; redox activity; selectivity; selectivity factor; stability; Biosensors; Chemical analysis; Chemical technology; Electrodes; Monitoring; Performance analysis; Platinum; Polymers; Stability; Transducers;
fLanguage :
English
Journal_Title :
Sensors Journal, IEEE
Publisher :
ieee
ISSN :
1530-437X
Type :
jour
DOI :
10.1109/JSEN.2003.814646
Filename :
1211081
Link To Document :
بازگشت