• DocumentCode
    1241543
  • Title

    Noninvasive measurement of heartbeat, respiration, snoring and body movements of a subject in bed via a pneumatic method

  • Author

    Watanabe, Kajiro ; Watanabe, Takashi ; Watanabe, Harumi ; Ando, Hisanori ; Ishikawa, Takayuki ; Kobayashi, Keita

  • Author_Institution
    Syst. Control Eng. Dept., Hosei Univ., Tokyo, Japan
  • Volume
    52
  • Issue
    12
  • fYear
    2005
  • Firstpage
    2100
  • Lastpage
    2107
  • Abstract
    We have developed a noninvasive pneumatics-based system by which to measure heartbeat, respiration, snoring, and body movements of a subject in bed. A thin, air-sealed cushion is placed under the bed mattress of the subject and the small movements attributable to human automatic vital functions are measured as changes in pressure using a pressure sensor having an almost flat frequency response from 0.1 to 5 kHz and a sensitivity of 56 mV/Pa. Using the newly developed system, heartbeat, respiration, apnea, snoring and body movements are clearly measured. In addition, the optimal signal-to-noise (S/N) ratio by which to evaluate the reliability of the heart rate measurement is presented. Heart rates were measured for four different body postures, 13 different subjects, four different bed mattresses, and three different sensor positions. For these measurements, the S/N ratios ranged from 15.9 to 23.5 dB, and so were determined to be reliable.
  • Keywords
    blood pressure measurement; pneumatic systems; pneumodynamics; pressure sensors; sleep; 0.1 to 5 kHz; bed mattresses; body movements; body postures; heart rate; heartbeat,; human automatic vital functions; noninvasive pneumatics-based system; pressure sensor; respiration; snoring; Frequency measurement; Frequency response; Heart beat; Humans; Motion measurement; Noninvasive treatment; Pressure measurement; Sensor phenomena and characterization; Sensor systems; Sleep apnea; Body movements; health monitoring; heartbeat; noninvasive measurement; pressure sensor; respiration; snoring; vital sign; Beds; Diagnosis, Computer-Assisted; Equipment Design; Equipment Failure Analysis; Heart Rate; Humans; Manometry; Movement; Polysomnography; Respiratory Mechanics; Snoring;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2005.857637
  • Filename
    1542461