Title :
Behavior of Crosstalk Loss for Adjacent Pairs at Low Frequencies
Author_Institution :
Bell-Northern Research, Ottawa, Ont., Canada
fDate :
9/1/1975 12:00:00 AM
Abstract :
Measurements at the Northern Electric cable plant in Lachine [2] and elsewhere [3],[4] showed that at low frequencies near-end crosstalk loss (NEXT) and far-end crosstalk loss (FEXT) for adjacent pairs do not have slopes of 15 dB/decade and 20 dB/ decade, respectively. In this paper an approximation predicts a slope of 5 dB/decade for NEXT and long cable and 10 dB/decade for FEXT.
Keywords :
Crosstalk; Wire communications; Attenuation; Capacitance; Communication cables; Crosstalk; Electric variables measurement; Frequency measurement; Inductance; Mutual coupling; Power cables; Wire;
Journal_Title :
Communications, IEEE Transactions on
DOI :
10.1109/TCOM.1975.1092904