DocumentCode
1244661
Title
The use of conducting shields for increasing the operating current limit in a rail launcher
Author
Drobyshevski, E.M. ; Yuferev, S.V.
Author_Institution
A.F. Ioffe Physicotech. Inst., Acad. of Sci., St. Petersburg, Russia
Volume
31
Issue
1
fYear
1995
Firstpage
291
Lastpage
294
Abstract
A new optimization technique to reduce thermal and repulsive loads in a railgun is described, The structural components (containment conductor) of the railgun were used as an electromagnetic shield to control rail current distribution. In summary, by optimizing the position of the shield in the railgun we were able to greatly reduce the dynamic deformation of the rails and increase the maximum permissible total rail current and the projectile force without heat damage of the rail surface.<>
Keywords
current distribution; electric current control; electromagnetic shielding; optimisation; railguns; conducting shields; containment conductor; electromagnetic shield; operating current limit increase; optimization technique; projectile force increase; rail current distribution control; rail dynamic deformation reduction; rail launcher; repulsive loads reduction; structural components; thermal loads reduction; total rail current increase; Coaxial components; Conductors; Current distribution; Electromagnetic forces; Frequency; Integral equations; Projectiles; Railguns; Rails; Thermal loading;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/20.364674
Filename
364674
Link To Document