DocumentCode
1245207
Title
Radiation-induced attenuation in detectors using Cerenkov radiator or plastic scintillator
Author
Negre, Jean Paul ; Ducrocq, Cyril
Author_Institution
Dept. des Mesures, CEA, Bruyeres-le-Chatel, France
Volume
42
Issue
1
fYear
1995
fDate
2/1/1995 12:00:00 AM
Firstpage
27
Lastpage
32
Abstract
Some radiation detectors, using Cerenkov radiator or plastic scintillator, operate at very high dose rates. The accumulated dose greatly affects their performance. In fast and high gamma pulse environments, detector linearity is of great concern. In this paper we give some results that show the discrepancy which occurs when the transient radiation-induced attenuation is too high. We also give a model that can be used to determine maximum dose values for gamma pulse measurements and to correct spoiled data
Keywords
Cherenkov counters; gamma-ray detection; gamma-ray effects; solid scintillation detectors; Cerenkov radiator; accumulated dose; detector linearity; fast pulse environments; gamma pulse measurements; high gamma pulse environments; maximum dose values; plastic scintillator; radiation detectors; radiation-induced attenuation; spoiled data; transient radiation-induced attenuation; very high dose rates; Attenuation; Gamma ray detection; Optical attenuators; Optical fiber testing; Optical fibers; Optical materials; Optical waveguides; Plastics; Radiation detectors; Silicon compounds;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.364878
Filename
364878