Title :
Comments, with reply, on "Optimal respiratory controller structures
Author :
Poon, C.-S. ; Swanson, G.D. ; Robbins, P.A.
Author_Institution :
Dept. of Electr. & Electron. Eng., North Dakota State Univ., Fargo, ND, USA
fDate :
5/1/1988 12:00:00 AM
Abstract :
The commenter points out several defects in the modified respiratory controller model described in the above paper (ibid., vol.BME-33, p.677-80, 1986). He argues that: (1) the assumption of additive response characteristics is problematic, (2) the proposed additive controller structure is inherently redundant and unnecessary, and (3) these ambiguities aside, an alternative additive-type optimal controller model exists which has a different neuronal structure than the one described by the authors, i.e. the additive controller structure is not unique. The authors provide a counterargument.<>
Keywords :
biocontrol; additive controller structure; neuronal structure; Biomedical measurements; Chemical sensors; Differential equations; Neodymium; Optimal control; Predictive models; Testing; Voltage-controlled oscillators; Exertion; Humans; Hypercapnia; Models, Biological; Respiration;
Journal_Title :