DocumentCode :
1248261
Title :
Development and laboratory testing of a 138 kV PPP-insulated joint for commercial application
Author :
Walldorf, S.P. ; Chu, H. ; ElBadaly, H.
Author_Institution :
MAC Products Inc., Kearny, NJ, USA
Volume :
5
Issue :
2
fYear :
1990
fDate :
4/1/1990 12:00:00 AM
Firstpage :
799
Lastpage :
805
Abstract :
The design, development, and laboratory testing of a PPP (paper/polypropylene/paper)-insulated joint for commercial application on 1389 kV PPP-insulated cable are presented. The design approach taken is conservative and addresses the typical variations in field conditions and in skill and workmanship of the splicing. Joint construction details, including choice of connector, taping structure, and joint mechanical reinforcement, are discussed. The test criteria are described, and results are presented
Keywords :
cable insulation; cable jointing; cable testing; organic insulating materials; power cables; 138 kV; cable jointing; connector; design; development; mechanical reinforcement; organic insulating materials; paper/polypropylene/paper; power cable testing; splicing; taping; Breakdown voltage; Conductors; Connectors; Copper; Dielectric breakdown; Dielectrics and electrical insulation; Impulse testing; Laminates; Splicing; Stress;
fLanguage :
English
Journal_Title :
Power Delivery, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8977
Type :
jour
DOI :
10.1109/61.53086
Filename :
53086
Link To Document :
بازگشت