DocumentCode :
124829
Title :
Characterization of autoemission reflection at high frequencies for precise radiometer calibration
Author :
Houtz, D. ; Gasiewski, Albin J. ; Kraft, Daniel ; Leuski, V.
Author_Institution :
Nat. Inst. of Stand. & Technol., Boulder, CO, USA
fYear :
2014
fDate :
8-11 Jan. 2014
Firstpage :
1
Lastpage :
1
Abstract :
Summary form only given. The close coupling of antenna horns and pyramidal calibration loads on passive microwave radiometers is standard practice for operational spaceborne calibration. However, various radiometer front end architectures can allow radiation leakage (autoemission) out of the horn which can produce local oscillator standing waves along with upper and lower sideband signals reflected back into the radiometer. Calibration loads are designed to minimize such reflections but this effect still has a measureable effect with error amplitudes that are important for radiometric studies of long term trends in climate. Front end RF isolators and low noise amplifiers (LNAs) can be unavailable or expensive at frequencies above ~90 GHz, in which case there is little protection against autoemission. This study investigates the standing waves resulting from a pyramidal microwave calibration target due to autoemission from a 183 GHz radiometer. The radiometer measures 7 channels using a double side band (DSB) architecture with RF offsets from the LO ranging from 0.55 GHz to 16 GHz. A calibration target is stepped in distance while brightness temperatures are continuously sampled. By detrending gain variations, and coherently averaging the brightness, standing waveforms are obtained. A Fourier transform is subsequently used to analyze the data in the spatial frequency domain. Contributing sources of the autoemission are identified as due to local oscillator (LO) reflections and the reflected RF passband noise from one of the two sidebands of the DSB radiometer. The standard deviation of the standing wave is statistically calculated and compared for a number of measurement cases. Two pyramidal targets are investigated at 4 alignment positions, including over the tip, valley, and combinations of the two. Standing wave results from a 55 GHz radiometer with similar processing techniques were presented at NRSM in 2012 and are compared to results from this study. Results f- om reflections from a flat aluminum plate are studied. From Fourier analysis, the highest autoemission returns over the targets were typically found to be at the frequency corresponding to twice the lower sideband frequency.
Keywords :
Fourier transforms; calibration; electromagnetic wave reflection; microwave measurement; millimetre wave detectors; radiometers; DSB architecture; Fourier analysis; Fourier transform; LNA; RF passband noise; autoemission reflection; brightness temperatures; double side band architecture; flat aluminum plate; frequency 0.55 GHz to 16 GHz; frequency 183 GHz; frequency 55 GHz; front end RF isolators; local oscillator reflections; local oscillator standing waves; low noise amplifiers; pyramidal microwave calibration target; radiation leakage; radiometer calibration; spatial frequency domain; Amplitude modulation; Calibration; Educational institutions; Microwave antennas; Microwave radiometry; Radio frequency; Reflection;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Radio Science Meeting (USNC-URSI NRSM), 2014 United States National Committee of URSI National
Conference_Location :
Boulder, CO
Print_ISBN :
978-1-4799-3119-4
Type :
conf
DOI :
10.1109/USNC-URSI-NRSM.2014.6928046
Filename :
6928046
Link To Document :
بازگشت