• DocumentCode
    1249204
  • Title

    Residual stresses in a doubly clad fiber with depressed inner cladding (DIC)

  • Author

    Park, Y. ; Oh, K. ; Paek, U.C. ; Kim, D.Y. ; Kurkjian, Charles R.

  • Author_Institution
    Dept. of Inf. & Commun., Kwangju Inst. of Sci. & Technol., South Korea
  • Volume
    17
  • Issue
    10
  • fYear
    1999
  • fDate
    10/1/1999 12:00:00 AM
  • Firstpage
    1823
  • Lastpage
    1834
  • Abstract
    Thermal and mechanical stresses developed in concentric three-layered optical fiber-core, and inner and outer cladding, have been thoroughly studied for various concentrations of dopants and geometric structures. In order to examine the parametric results of thermal stresses in preforms, the stresses were measured with a polariscope. The results agreed well with the theoretical calculations. The thermal stresses were calculated for three temperature ranges in which the glass in each layer has a different thermal expansion coefficient. The mechanical stresses were studied considering the normal stress in the molten neck down region and its development with time. In order to include the time dependence of the stress below softening point, Maxwell´s one dimensional viscoelasticity was applied. In a parametric study, the analyzes were carried out based on the fiber parameters such as relative index difference, ratio of clad to core, and depressed relative index difference. With an increase of core index above the silica, the thermal stresses in core increased linearly, but the depressed inner clad does not affect the stresses in core. From the parametric studies and modeling it was found that when the depressed inner cladding (DIC) layer has a large cross-section or high dopant concentration, the mechanical stress in core change from compression to tension
  • Keywords
    internal stresses; mechanical strength; optical fibre cladding; polarimeters; thermal stresses; viscoelasticity; 1D viscoelasticity; concentric three-layered optical fiber-core; core index; depressed inner cladding; dopants; doubly clad fiber; geometric structures; high dopant concentration; mechanical stress; mechanical stresses; molten neck down; outer cladding; parametric results; polariscope; preforms; relative index difference; residual stresses; temperature ranges; thermal expansion coefficient; thermal stresses; Geometrical optics; Glass; Optical fiber polarization; Parametric study; Preforms; Residual stresses; Stress measurement; Temperature distribution; Thermal expansion; Thermal stresses;
  • fLanguage
    English
  • Journal_Title
    Lightwave Technology, Journal of
  • Publisher
    ieee
  • ISSN
    0733-8724
  • Type

    jour

  • DOI
    10.1109/50.793760
  • Filename
    793760