• DocumentCode
    1250007
  • Title

    Miniature optical fibre ultrasonic hydrophone using a Fabry-Perot polymer film interferometer

  • Author

    Beard, P.C. ; Mills, T.N.

  • Author_Institution
    Dept. of Med. Phys. & Bioeng., Univ. Coll. London, UK
  • Volume
    33
  • Issue
    9
  • fYear
    1997
  • fDate
    4/24/1997 12:00:00 AM
  • Firstpage
    801
  • Lastpage
    803
  • Abstract
    An optical fibre hydrophone for the measurement and detection of ultrasound is described. The active sensing element consists of a low finesse Fabry-Perot polymer film interferometer bonded to the tip of an optical fibre, of 50 μm core diameter and 0.25 mm outer diameter. Sensitivity was found to be 114 mV/MPa with an acoustic noise floor of 15 kPa over a 25 MHz bandwidth
  • Keywords
    Fabry-Perot interferometers; fibre optic sensors; hydrophones; polymer films; ultrasonic measurement; 0.25 mm; 25 MHz; 50 micron; Fabry-Perot polymer film interferometer; acoustic noise floor; active sensing element; core diameter; optical fibre; optical fibre ultrasonic hydrophone; outer diameter; ultrasound detection;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:19970545
  • Filename
    590258