  • Abstract
    This paper investigates the performance of silicon microstrip detectors after heavy irradiation. Full-size prototype sensors (53 /spl times/ 64 mm/sup 2/) designed for the CMS Tracker have been irradiated with protons and extensively studied in the laboratory and using a beam of minimum ionising particles operated at low temperature as foreseen for the Large Hadron Collider. We present results of large statistics measurements of collected charge, noise, position resolution, and hit finding efficiency for these irradiated detectors.
  • Keywords
    muon detection; particle spectrometers; position sensitive particle detectors; proton effects; semiconductor device noise; silicon radiation detectors; 53 mm; 64 mm; CMS tracker silicon detectors; CMS tracking system; Compact Muon Spectrometer; Large Hadron Collider; Si; collected charge; full-size prototype sensors; heavy irradiation; hit finding efficiency; inner tracker; irradiated detectors; low-resistivity substrates; minimum ionising particles; noise; position resolution; radiation resistance; silicon microstrip detectors; Collision mitigation; Detectors; Laboratories; Microstrip; Particle tracking; Protons; Prototypes; Silicon; Statistics; Temperature sensors;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.983256
  • Filename
    983256