• DocumentCode
    1251378
  • Title

    Experience with Large Hydro-Generators at Grand Coulee

  • Author

    Moore, V.A.

  • Author_Institution
    Canadian General Electric Co., Ltd., Peterborough, ON, Canada
  • Issue
    10
  • fYear
    1983
  • Firstpage
    25
  • Lastpage
    25
  • Abstract
    The design and construction of the three 826 MV??A hydro-generators for the Grand Coulee Third Power Plant represents a significant achievement. A number of factors conspired to create a situation wherein local contact occurred between the stator and rotors of one unit. This paper outlines the events leading up to this incident, describes investigative work, and remedial measures taken to reestablish the intended design parameters.
  • Keywords
    Heating; Instruments; Power generation; Q measurement; Rotors; Stators; Telemetry; Temperature measurement; Temperature sensors; Testing;
  • fLanguage
    English
  • Journal_Title
    Power Engineering Review, IEEE
  • Publisher
    ieee
  • ISSN
    0272-1724
  • Type

    jour

  • DOI
    10.1109/MPER.1983.5520068
  • Filename
    5520068