• DocumentCode
    1251660
  • Title

    Target detectability in acoustic elastography

  • Author

    Bilgen, Mehmet

  • Author_Institution
    Dept. of Radiol., Univ. of Texas-Houston Med. Sch., Houston, TX, USA
  • Volume
    46
  • Issue
    5
  • fYear
    1999
  • Firstpage
    1128
  • Lastpage
    1133
  • Abstract
    The clinically relevant task of visually detecting low contrast targets in noisy strain images estimated from ultrasonic signals is studied. Detectability is measured quantitatively using contrast-to-noise ratio (CNR) analysis. Contrast in strain images is generated by a complex interaction among the soft tissue elasticity shear modulus distribution, target shape and location in the stress field, and external boundary conditions. Although a large strain variation is preferred for enhancing the contrast, this also increases the signal-dependent noise in strain estimates in a nonlinear fashion. Therefore, understanding the tradeoffs between contrast and noise is necessary for improving the diagnostic performance of strain imaging. In this paper, targets with slab, cylindrical, and spherical geometries are studied. Strains in the target and background and the precision of their estimates are described in terms of the corresponding shear modulus values for each geometry. These results are then incorporated into the CNR expression to investigate the changes in target detectability with the variation of shear modulus in the target and the ultrasonic signal parameters (echo signal-to-noise ratio and inverse fractional bandwidth) as well as the signal processing variables (time-bandwidth product and fractional window overlap).
  • Keywords
    biomedical ultrasonics; elasticity; medical image processing; noise; shear modulus; ultrasonic imaging; CNR expression; US signal parameters; acoustic elastography; contrast-to-noise ratio analysis; cylindrical geometry; diagnostic performance; echo SNR; elastographic imaging; external boundary conditions; fractional window overlap; inverse fractional bandwidth; low contrast targets; noisy strain images; shear modulus values; signal processing variables; slab geometry; soft tissue elasticity shear modulus distribution; spherical geometry; strain imaging; stress field; target detectability; target location; target shape; time-bandwidth product; tissue elasticity; ultrasonic signals; Acoustic measurements; Acoustic noise; Acoustic signal detection; Biological tissues; Capacitive sensors; Geometry; Image generation; Noise shaping; Signal processing; Ultrasonic variables measurement;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/58.796118
  • Filename
    796118