DocumentCode :
1255115
Title :
The large gap case for HV insulation in vacuum
Author :
Spolaore, P. ; Bisoffi, G. ; Cervellera, F. ; Pengo, R. ; Scarpa, F.
Author_Institution :
I.N.F.N. Laboratori Nazionali di Legnaro, Italy
Volume :
4
Issue :
4
fYear :
1997
fDate :
8/1/1997 12:00:00 AM
Firstpage :
389
Lastpage :
393
Abstract :
A test setup able to accommodate dish shaped electrodes for gaps up to ~20 cm is being used to study large gap effects. This experiment, in connection with other authors´ experiments, underlines the three more characteristic aspects of the large gap case: a voltage effect, a current effect and a gas effect. The difficulty of energy dissipation by surface processes at increasing penetration depth of the energy deposit gives an interesting interpretative perspective to the behavior of large gap, HV devices
Keywords :
electrodes; insulation testing; surface discharges; vacuum insulation; 10 to 20 cm; HV devices; HV insulation; current effect; dish shaped electrodes; energy deposit; energy dissipation; gas effect; large gap effects; penetration depth; surface processes; test setup; vacuum insulation; voltage effect; Electrodes; Energy dissipation; Helium; Insulation; Rough surfaces; Steel; Surface roughness; Testing; Vacuum systems; Voltage;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/94.625353
Filename :
625353
Link To Document :