• DocumentCode
    125572
  • Title

    Study on the unknown thru calibration technique

  • Author

    Zhang Na ; Zhang Guo Hua ; Chen Ting ; Liu Jie

  • Author_Institution
    Beijing Inst. of Radio Metrol. & Meas., Beijing, China
  • fYear
    2014
  • fDate
    16-23 Aug. 2014
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    This paper particularly introduces error model, theory, algorithm of the unknown thru calibration technique, and shows why the thru standard has an approximate delay expression. Experiment for coaxial non-insertable device has been processed showing that the unknown thru calibration technique has a great increase in the measurement accuracy and consistency.
  • Keywords
    approximation theory; calibration; measurement errors; measurement standards; approximate delay expression; coaxial noninsertable device; measurement error model; unknown thru calibration technique; Calibration; Facsimile; Measurement uncertainty; Metrology; Ports (Computers); Reflection; Standards;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    General Assembly and Scientific Symposium (URSI GASS), 2014 XXXIth URSI
  • Conference_Location
    Beijing
  • Type

    conf

  • DOI
    10.1109/URSIGASS.2014.6929005
  • Filename