• DocumentCode
    1257162
  • Title

    Time-Frequency Analysis of Accelerometry Data for Detection of Myoclonic Seizures

  • Author

    Nijsen, Tamara M E ; Aarts, Ronald M. ; Cluitmans, Pierre J M ; Griep, Paul A M

  • Author_Institution
    Epilepsy Centre Kempenhaeghe, Heeze, Netherlands
  • Volume
    14
  • Issue
    5
  • fYear
    2010
  • Firstpage
    1197
  • Lastpage
    1203
  • Abstract
    Four time-frequency and time-scale methods are studied for their ability of detecting myoclonic seizures from accelerometric data. Methods that are used are: the short-time Fourier transform (STFT), the Wigner distribution (WD), the continuous wavelet transform (CWT) using a Daubechies wavelet, and a newly introduced model-based matched wavelet transform (MOD). Real patient data are analyzed using these four time-frequency and time-scale methods. To obtain quantitative results, all four methods are evaluated in a linear classification setup. Data from 15 patients are used for training and data from 21 patients for testing. Using features based on the CWT and MOD, the success rate of the classifier was 80%. Using STFT or WD-based features, the classification success is reduced. Analysis of the false positives revealed that they were either clonic seizures, the onset of tonic seizures, or sharp peaks in “normal” movements indicating that the patient was making a jerky movement. All these movements are considered clinically important to detect. Thus, the results show that both CWT and MOD are useful for the detection of myoclonic seizures. On top of that, MOD has the advantage that it consists of parameters that are related to seizure duration and intensity that are physiologically meaningful. Furthermore, in future work, the model can also be useful for the detection of other motor seizure types.
  • Keywords
    Fourier analysis; Wigner distribution; acceleration measurement; accelerometers; biomedical measurement; medical signal processing; muscle; patient diagnosis; time-frequency analysis; wavelet transforms; CWT; Daubechies wavelet; MOD; STFT; WD; Wigner distribution; accelerometry data; continuous wavelet transform; model based matched wavelet transform; motor seizure types; myoclonic seizure detection; short time Fourier transform; time scale methods; time-frequency analysis; Continuous wavelet transforms; Feature extraction; Fourier transforms; Muscles; Time frequency analysis; Accelerometry (ACM); model; seizure detection; time-frequency analysis; Acceleration; Arm; Discriminant Analysis; Epilepsies, Myoclonic; Fourier Analysis; Humans; Models, Statistical; Monitoring, Ambulatory; Movement; Seizures; Signal Processing, Computer-Assisted;
  • fLanguage
    English
  • Journal_Title
    Information Technology in Biomedicine, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1089-7771
  • Type

    jour

  • DOI
    10.1109/TITB.2010.2058123
  • Filename
    5523946