• DocumentCode
    1258382
  • Title

    Sensor-Enabled RFID System for Monitoring Arm Activity: Reliability and Validity

  • Author

    Barman, J. ; Uswatte, G. ; Ghaffari, T. ; Sokal, B. ; Byrom, E. ; Trinh, E. ; Brewer, M. ; Varghese, C. ; Sarkar, N.

  • Author_Institution
    Dept. of Biomed. Eng., Univ. of Alabama, Birmingham, AL, USA
  • Volume
    20
  • Issue
    6
  • fYear
    2012
  • Firstpage
    771
  • Lastpage
    777
  • Abstract
    After stroke, capacity to complete tasks in the treatment setting with the more-affected arm is an unreliable index of actual use of that extremity in daily life. Available objective methods for monitoring real-world arm use rely on placing movement sensors on patients. These methods provide information on amount but not type of arm activity, e.g., functional versus nonfunctional movement. This paper presents an approach that places sensors on patients and household objects, overcoming this limitation. An accelerometer and the transmitter component of a radio-frequency proximity sensor are attached to objects; the receiver component is attached to the arm of interest. The receiver triggers an on-board radio-frequency identification tag to signal proximity when that arm is within 23 cm of an instrumented object. In benchmark testing, this system detected perfectly which arm was used to move the target object on 200 trials. In a laboratory study with 35 undergraduates, increasing the amount of time target objects were moved with the arm of interest resulted in a corresponding increase in system output (p <; 0.0001) . Moreover, measurement error was low (≤2.5%). The results support this system´s reliability and validity in individuals with unimpaired movement; testing is now warranted in stroke patients.
  • Keywords
    accelerometers; benchmark testing; biomechanics; biomedical equipment; biomedical telemetry; measurement errors; patient monitoring; patient treatment; radiofrequency identification; reliability; transmitters; accelerometer; arm activity monitoring; benchmark testing; functional movement; measurement error; movement sensors; nonfunctional movement; on-board radiofrequency identification tag; radiofrequency proximity sensor; receiver component; reliability; sensor-enabled RFID system; signal proximity; stroke; transmitter component; treatment setting; unimpaired movement; Accelerometers; Arm; Patient monitoring; Radiofrequency identification; Receivers; Sensitivity; Accelerometer; ambulatory monitoring in stroke survivors; proximity sensor; radio-frequency identification (RFID); Acceleration; Activities of Daily Living; Adolescent; Adult; Arm; Benchmarking; Data Interpretation, Statistical; Female; Hand; Humans; Male; Middle Aged; Monitoring, Ambulatory; Movement; Psychomotor Performance; Radio; Radio Waves; Reproducibility of Results; Young Adult;
  • fLanguage
    English
  • Journal_Title
    Neural Systems and Rehabilitation Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1534-4320
  • Type

    jour

  • DOI
    10.1109/TNSRE.2012.2210561
  • Filename
    6259885