DocumentCode :
1259320
Title :
Dynamic selective harmonic elimination of a three-level inverter used for static VAr compensation
Author :
Ran, L. ; Holdsworth, L. ; Putrus, G.A.
Author_Institution :
Sch. of Eng., Northumbria Univ., Newcastle upon Tyne, UK
Volume :
149
Issue :
1
fYear :
2002
fDate :
1/1/2002 12:00:00 AM
Firstpage :
83
Lastpage :
89
Abstract :
The paper investigates the harmonic interaction between the AC and DC sides of a three-level inverter used as a static synchronous VAr compensator (STATCOM). It is illustrated that due to the third harmonic voltage across each DC side capacitor, the conventional selective harmonic elimination modulation (SHEM) may not actually eliminate the target harmonics when the system is on load. A new modulation method, which dynamically adjusts the switching angles according to the operating point, is proposed to overcome this difficulty. The proposed method is verified using simulation and experimental tests.
Keywords :
DC-AC power convertors; flexible AC transmission systems; harmonic distortion; harmonics suppression; invertors; power conversion harmonics; power transmission control; static VAr compensators; DC side capacitor; STATCOM; dynamic selective harmonic elimination; harmonic interaction; modulation method; operating point; static VAr compensation; static synchronous VAr compensator; switching angles; target harmonics; third harmonic voltage; three-level inverter;
fLanguage :
English
Journal_Title :
Generation, Transmission and Distribution, IEE Proceedings-
Publisher :
iet
ISSN :
1350-2360
Type :
jour
DOI :
10.1049/ip-gtd:20020082
Filename :
989211
Link To Document :
بازگشت