• DocumentCode
    1260107
  • Title

    Minimization of number of metrological parameters for data acquisition systems

  • Author

    Didenko, Valeriy I. ; Movchan, Andrey L.

  • Author_Institution
    Dept. of Inf. & Meas. Technics, Moscow Power Eng. Inst., Russia
  • Volume
    51
  • Issue
    1
  • fYear
    2002
  • fDate
    2/1/2002 12:00:00 AM
  • Firstpage
    88
  • Lastpage
    91
  • Abstract
    This paper considers the metrological model of the data acquisition system (DAS). The main attention is focused on the DAS on the basis of the sigma-delta analog-to-digital converter. The choice of the minimum number of parameters of the DAS allowing evaluation of the uncertainty of A/D conversion with reasonable accuracy is investigated
  • Keywords
    data acquisition; measurement uncertainty; sigma-delta modulation; A/D conversion; DAS; accuracy; data acquisition systems; metrological model; metrological parameters; sigma-delta analog-to-digital converter; uncertainty; Analog-digital conversion; Clocks; Data acquisition; Delta-sigma modulation; Frequency conversion; Hardware; Minimization; Power measurement; Power supplies; Voltage;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.989907
  • Filename
    989907