DocumentCode
1261670
Title
Simultaneous Reconstruction of Activity and Attenuation in Time-of-Flight PET
Author
Rezaei, A. ; Defrise, M. ; Bal, G. ; Michel, C. ; Conti, M. ; Watson, C. ; Nuyts, J.
Author_Institution
Nucl. Med. Dept., K.U. Leuven, Leuven, Belgium
Volume
31
Issue
12
fYear
2012
Firstpage
2224
Lastpage
2233
Abstract
In positron emission tomography (PET) and single photon emission tomography (SPECT), attenuation correction is necessary for quantitative reconstruction of the tracer distribution. Previously, several attempts have been made to estimate the attenuation coefficients from emission data only. These attempts had limited success, because the problem does not have a unique solution, and severe and persistent “cross-talk” between the estimated activity and attenuation distributions was observed. In this paper, we show that the availability of time-of-flight (TOF) information eliminates the cross-talk problem by destroying symmetries in the associated Fisher information matrix. We propose a maximum-a-posteriori reconstruction algorithm for jointly estimating the attenuation and activity distributions from TOF PET data. The performance of the algorithm is studied with 2-D simulations, and further illustrated with phantom experiments and with a patient scan. The estimated attenuation image is robust to noise, and does not suffer from the cross-talk that was observed in non-TOF PET. However, some constraining is still mandatory, because the TOF data determine the attenuation sinogram only up to a constant offset.
Keywords
image denoising; image reconstruction; medical image processing; phantoms; positron emission tomography; radioactive tracers; single photon emission computed tomography; 2D simulation; Fisher information matrix; TOF PET data; activity distributions; attenuation coefficients; attenuation correction; attenuation distributions; attenuation sinogram; constant offset; cross-talk problem; emission data; estimated activity; estimated attenuation imaging; maximum-a-posteriori reconstruction algorithm; patient scan; performance algorithm; persistent cross-talk; phantom; positron emission tomography; quantitative reconstruction; robust noise; simultaneous reconstruction; single photon emission tomography; time-of-fight information; time-of-flight PET; tracer distribution; Attenuation; Image reconstruction; Image resolution; Joints; Maximum likelihood estimation; Phantoms; Positron emission tomography; Activity and attenuation cross-talk; attenuation correction; joint estimation; maximum likelihood; time-of-flight (TOF) positron emission tomography (PET); Algorithms; Computer Simulation; Humans; Image Processing, Computer-Assisted; Phantoms, Imaging; Positron-Emission Tomography; Thorax;
fLanguage
English
Journal_Title
Medical Imaging, IEEE Transactions on
Publisher
ieee
ISSN
0278-0062
Type
jour
DOI
10.1109/TMI.2012.2212719
Filename
6264102
Link To Document