• DocumentCode
    1261863
  • Title

    Correlation of magnetoresistive sensitivity mapping (MSM) with spin stand performance

  • Author

    Schultz, Allan ; Louder, Darrell ; Hansen, Micheal ; DeVries, C. ; Nathe, Joel

  • Author_Institution
    Seagate Recording Heads, Bloomington, MN, USA
  • Volume
    35
  • Issue
    5
  • fYear
    1999
  • fDate
    9/1/1999 12:00:00 AM
  • Firstpage
    2571
  • Lastpage
    2573
  • Abstract
    Magnetoresistive sensitivity mapping (MSM) uses an AFM tip coated with a hard magnetic film as a flux source to provide a read sensitivity profile on a biased MR head. The resulting MSM signal is monitored using a modified electronics package attached to a standard probe microscope. MSM scans are compared with standard trackscans and μ-tracks of the same heads and are shown to detect the same anomalies in the read sensitivity profile
  • Keywords
    magnetic force microscopy; magnetic heads; magnetoresistive devices; sensitivity analysis; AFM tip; MSM signal; biased MR head; magnetic force microscopy; magnetoresistive sensitivity mapping; read sensitivity profile; spin stand performance; standard probe microscope; Atomic force microscopy; Force sensors; Magnetic field measurement; Magnetic films; Magnetic force microscopy; Magnetic heads; Magnetic recording; Magnetic sensors; Magnetoresistance; Signal mapping;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.800894
  • Filename
    800894