    Some researches on the safe use of electricity in coal mines

  • Author

    Thorn, W.M.

  • Volume
    62
  • Issue
    330
  • fYear
    1924
  • fDate
    6/1/1924 12:00:00 AM
  • Firstpage
    481
  • Lastpage
    491
  • Abstract
    The limiting electrical conditions under which ignition of coal dust and firedamp may occur have been worked at in the author´s laboratory for the past 14 years, as part of a general investigation of the mechanism of ignition of gases. The paper contains an account of some results of practical interest, and deals with the electrical ignition of coal dust alone, coal dust with gas present, of methane and associated gases by disruptive sparks, steady or impulsive, transient arcs, direct or alternating, with varied voltage and frequency, in all percentages of mixture with air. Examples are given of the application of the results to promote safety in mines, notably the influence of currents of higher frequency than usual, of safety bells, safety lamps which give an alarm signal when dangerous mixtures of gas occur, and an improved earthing plate.
  • Keywords
    power distribution, traction and lighting; switching and controlling;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineers, Journal of the Institution of
  • Publisher
    iet
  • Type

    jour

  • DOI
    10.1049/jiee-1.1924.0068
  • Filename
    5313085