Title :
Measurement performance testing for nonsinusoidal environments
Author :
Ghosh, P.K. ; Durante, L.G.
Author_Institution :
Dept. of Electr. & Comput. Eng., Syracuse Univ., NY, USA
fDate :
11/1/1999 12:00:00 AM
Abstract :
A comparative study of the measurement accuracy capabilities of solid state watthour meters and other commercially available measurement instruments was performed. This study proposes a set of mathematically designed “waveforms” that could be used as a standard for the uniform, meaningful and reproducible evaluation testing of solid state watthour meters designed for use in nonsinusoidal environments. The test waveforms were theoretically developed based on an extensive database of field captured distorted waveforms that, in most cases, were monitored and recorded during power quality investigations over the last five years. Experimentation was performed using both the theoretically developed waveforms and the field captured waveforms
Keywords :
calibration; harmonic distortion; power measurement; power supply quality; power system harmonics; watthour meters; measurement accuracy; measurement instruments; measurement performance testing; nonsinusoidal supply environments; power quality; solid state watthour meters; Electric variables measurement; Guidelines; Harmonic distortion; Laboratories; Power system harmonics; Power systems; Semiconductor materials; Solid state circuits; Testing; Watthour meters;
Journal_Title :
Power Systems, IEEE Transactions on