DocumentCode :
1264518
Title :
A cone-beam reconstruction algorithm for circle-plus-arc data-acquisition geometry
Author :
Wang, Xiaohui ; Ning, Ruola
Author_Institution :
Dept. of Radiology, Rochester Univ., NY, USA
Volume :
18
Issue :
9
fYear :
1999
Firstpage :
815
Lastpage :
824
Abstract :
In cone-beam computerized tomography (CT), projections acquired with the focal spot constrained on a planar orbit cannot provide a complete set of data to reconstruct the object function exactly. There are severe distortions in the reconstructed noncentral transverse planes when the cone angle is large. In this work, a new method is proposed which can obtain a complete set of data by acquiring cone-beam projections along a circle-plus-arc orbit. A reconstruction algorithm using this circle-plus-arc orbit is developed, based on the Radon transform and Grangeat´s formula. This algorithm first transforms the cone-beam projection data of an object to the first derivative of the three-dimensional (3-D) Radon transform, using Grangeat´s formula, and then reconstructs the object using the inverse Radon transform. In order to reduce interpolation errors, new rebinning equations have been derived accurately, which allows one-dimensional (1-D) interpolation to be used in the rebinning process instead of 3-D interpolation, A noise-free Defrise phantom and a Poisson noise-added Shepp-Logan phantom were simulated and reconstructed for algorithm validation. The results from the computer simulation indicate that the new cone-beam data-acquisition scheme can provide a complete set of projection data and the image reconstruction algorithm can achieve exact reconstruction. Potentially, the algorithm can be applied in practice for both a standard CT gantry-based volume tomographic imaging system and a C-arm-based cone-beam tomographic imaging system, with little mechanical modification required.
Keywords :
Radon transforms; computerised tomography; data acquisition; image reconstruction; interpolation; medical image processing; CT; Grangeat´s formula; Poisson noise-added Shepp-Logan phantom; Radon transform; circle-plus-arc data-acquisition geometry; cone angle; cone-beam computerized tomography; cone-beam reconstruction algorithm; exact reconstruction; focal spot; interpolation errors; mechanical modification; medical diagnostic imaging; planar orbit; rebinning equations; reconstructed noncentral transverse planes; severe distortions; Computed tomography; Computer errors; Geometry; Image reconstruction; Imaging phantoms; Interpolation; Noise reduction; Poisson equations; Reconstruction algorithms; Transforms; Algorithms; Computer Simulation; Humans; Image Processing, Computer-Assisted; Tomography, X-Ray Computed;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/42.802759
Filename :
802759
Link To Document :
بازگشت