DocumentCode :
1266219
Title :
Indirect Current Control for Seamless Transfer of Three-Phase Utility Interactive Inverters
Author :
Kwon, Junbum ; Yoon, Sunjae ; Choi, Sewan
Author_Institution :
LS Ind. Syst., Anyang, South Korea
Volume :
27
Issue :
2
fYear :
2012
Firstpage :
773
Lastpage :
781
Abstract :
This paper proposes an indirect current control algorithm for seamless transfer of three-phase utility-interactive voltage source inverters. With the proposed method the inverter is able to provide critical loads with a stable and seamless voltage during the whole transition period including both clearing time and control mode change. The LCL filter design which is suitable for the indirect current control is also proposed to meet the harmonic limits. The proposed control method is validated through simulation and experiment.
Keywords :
electric current control; invertors; power filters; LCL filter design; indirect current control algorithm; seamless transfer; seamless voltage; three-phase utility-interactive voltage source inverters; Capacitors; Inductors; Inverters; Power harmonic filters; Switches; Transient analysis; Voltage control; Indirect current control; LCL filter; seamless transfer; three-phase inverter; utility-interactive inverter;
fLanguage :
English
Journal_Title :
Power Electronics, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8993
Type :
jour
DOI :
10.1109/TPEL.2011.2161335
Filename :
5942180
Link To Document :
بازگشت