• DocumentCode
    126801
  • Title

    Analysis of temperature increase in the post-wall waveguide type exposure apparatus in vitro

  • Author

    Shiina, Tsuyoshi ; Sasaki, Kazuhiko ; Suzuki, Yuya ; Taki, Masato

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Tokyo Metropolitan Univ., Hachioji, Japan
  • fYear
    2014
  • fDate
    16-23 Aug. 2014
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    We analyzed temperature increase in the post-wall waveguide type millimeter-wave exposure apparatus in vitro. This results show a similar tendency to the experimental results. The cooling effect in a state of natural cooling was 35-55 % by using heat sink as a basic cooling element. It allows the evaluations for non-thermal effects to expose MMWs of higher intensity than conventional exposure apparatus.
  • Keywords
    biological effects of microwaves; biological techniques; biothermics; heat sinks; millimetre wave devices; basic cooling element; conventional exposure apparatus; heat sink; natural cooling; nonthermal effects; post-wall waveguide type millimeter-wave exposure apparatus in vitro; temperature analysis; Heat sinks; Heat transfer; Heating; Millimeter wave technology; Substrates; Temperature measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    General Assembly and Scientific Symposium (URSI GASS), 2014 XXXIth URSI
  • Conference_Location
    Beijing
  • Type

    conf

  • DOI
    10.1109/URSIGASS.2014.6930121
  • Filename
    6930121