DocumentCode
1269066
Title
Three-Phase Induction Generator for Single-Phase Line
Author
Smith, Otto J. M.
Author_Institution
University of California, Berkeley, CA
Issue
9
fYear
1987
Firstpage
39
Lastpage
39
Abstract
Hydroelectric generators of less than 20 kW can be served only by a single-phase line in remote areas. For high efficiency and low cost, a three-phase induction generator should be used. This three-phase generator can operate with balanced voltages and currents when the ``phase-splitting´´ circuit uses two capacitors connected to two different single-phase voltage sources.
Keywords
Boilers; Capacitors; Circuits; Control systems; Costs; Induction generators; Optimal control; Power system modeling; Samarium; Voltage;
fLanguage
English
Journal_Title
Power Engineering Review, IEEE