• DocumentCode
    1271086
  • Title

    The radiant efficiency and heat distribution of electric fires

  • Author

    Smith, Parker

  • Volume
    68
  • Issue
    405
  • fYear
    1930
  • fDate
    9/1/1930 12:00:00 AM
  • Firstpage
    1211
  • Lastpage
    1221
  • Abstract
    The paper details an attempt to measure the amount and distribution of the heat radiated from electric fires, employing the ¿Leeds¿ method already largely used for gas fires. A number of types of fire were tested, the radiant efficiency as measured lying generally within the limits of 55¿70 per cent, with an average of about 60 per cent. The results are fairly reliable for comparative purposes, and the error in the radiant efficiency determination is probably well within 5 per cent.
  • Keywords
    electric heating;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineers, Journal of the Institution of
  • Publisher
    iet
  • Type

    jour

  • DOI
    10.1049/jiee-1.1930.0135
  • Filename
    5314907