DocumentCode :
1278805
Title :
Effect of block-iterative acceleration on Ga-67 tumor detection in thoracic SPECT
Author :
Gifford, Howard C. ; King, Michael A. ; Narayanan, Manoj V. ; Pretorius, P. Hendrik ; Smyczynski, Mark S. ; Wells, R. Glenn
Author_Institution :
Dept. of Radiol., Massachusetts Univ. Med. Center, Worcester, MA, USA
Volume :
49
Issue :
1
fYear :
2002
fDate :
2/1/2002 12:00:00 AM
Firstpage :
50
Lastpage :
55
Abstract :
A combination of human localization receiver operating characteristic (LROC) and channelized Hotelling observer (CHO) ROC psychophysical studies were used to investigate how accelerated ordered-subset expectation maximization (OSEM) and rescaled block-iterative (RBI) EM reconstruction affect tumor detection in simulated Ga-67 SPECT images, The tumors were 1-cm-diameter spheres within the chest region of the three-dimensional mathematical cardiac-torso phantom. Previous work with iterative detector resolution compensation showed that eight iterations of the OSEM algorithm with a subset size of eight (16 subsets) offered optimal observer performance. For the LROC study in this paper, the OSEM and RBI algorithms were implemented using subset sizes P and iterations K that satisfied the relation P=K for P=1, 2, 4, and 8. The CHO was applied to reconstruction strategies that deviated from this relation. Results show that using P⩽2 penalized observer performance compared to strategies with larger subset sizes. Other researchers have reported on the more stable convergence and noise properties of the RBI algorithm [(Byrne, 1996) and (Lalush and Tsui, 2000)]. In a similar vein, we found that an RBI strategy with a subset size of P produced the same performance as an OSEM strategy with subset size 2P. As neither algorithm displayed a decisive advantage in speed over the other, we conclude that the RBI algorithm is the better choice for accelerating the Ga-67 reconstructions
Keywords :
algorithm theory; gallium; image reconstruction; iterative methods; medical image processing; radioisotopes; single photon emission computed tomography; tumours; Ga; Ga-67 reconstructions; Ga-67 tumor detection; accelerated ordered-subset expectation maximization; block-iterative acceleration; channelized Hotelling observer receiver operating characteristic psychophysical studies; chest region; human localization receiver operating characteristic; iterations; noise properties; optimal observer performance; ordered-subset expectation maximization algorithm; ordered-subset expectation maximization strategy; reconstruction strategies; rescaled block-iterative algorithm; rescaled block-iterative expectation maximization reconstruction; rescaled block-iterative strategy; simulated 67Ga SPECT images; spheres; subset size; thoracic SPECT; three-dimensional mathematical cardiac-torso phantom; tumor detection; Acceleration; Convergence; Detectors; Humans; Image reconstruction; Imaging phantoms; Iterative algorithms; Neoplasms; Psychology; Tumors;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2002.998680
Filename :
998680
Link To Document :