• DocumentCode
    128108
  • Title

    Protection of fixed monitoring station against interference from strong electromagnetic fields

  • Author

    Leontjev, Georgij

  • Author_Institution
    Radio Monitoring Dept., Commun. Regul. Authority, Vilnius, Lithuania
  • fYear
    2014
  • fDate
    1-4 Sept. 2014
  • Firstpage
    1092
  • Lastpage
    1095
  • Abstract
    Method for calculation of maximum permissible field strength at fixed radio monitoring station site is suggested. If the field strength of the radio stations situated near radio monitoring station does not exceed the calculated value, then they do not cause radio interferences to the radio monitoring station.
  • Keywords
    electromagnetic fields; radiofrequency interference; radiofrequency measurement; fixed radio monitoring station; maximum permissible field strength; radio interference; strong electromagnetic fields; Bandwidth; Electromagnetic compatibility; Equations; Mathematical model; Monitoring; Noise; Receivers; calculation of maximum permissible field strength; fixed radio monitoring station; harmful radio interference; intermodulation products;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility (EMC Europe), 2014 International Symposium on
  • Conference_Location
    Gothenburg
  • Type

    conf

  • DOI
    10.1109/EMCEurope.2014.6931065
  • Filename
    6931065