DocumentCode
128108
Title
Protection of fixed monitoring station against interference from strong electromagnetic fields
Author
Leontjev, Georgij
Author_Institution
Radio Monitoring Dept., Commun. Regul. Authority, Vilnius, Lithuania
fYear
2014
fDate
1-4 Sept. 2014
Firstpage
1092
Lastpage
1095
Abstract
Method for calculation of maximum permissible field strength at fixed radio monitoring station site is suggested. If the field strength of the radio stations situated near radio monitoring station does not exceed the calculated value, then they do not cause radio interferences to the radio monitoring station.
Keywords
electromagnetic fields; radiofrequency interference; radiofrequency measurement; fixed radio monitoring station; maximum permissible field strength; radio interference; strong electromagnetic fields; Bandwidth; Electromagnetic compatibility; Equations; Mathematical model; Monitoring; Noise; Receivers; calculation of maximum permissible field strength; fixed radio monitoring station; harmful radio interference; intermodulation products;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility (EMC Europe), 2014 International Symposium on
Conference_Location
Gothenburg
Type
conf
DOI
10.1109/EMCEurope.2014.6931065