DocumentCode :
128108
Title :
Protection of fixed monitoring station against interference from strong electromagnetic fields
Author :
Leontjev, Georgij
Author_Institution :
Radio Monitoring Dept., Commun. Regul. Authority, Vilnius, Lithuania
fYear :
2014
fDate :
1-4 Sept. 2014
Firstpage :
1092
Lastpage :
1095
Abstract :
Method for calculation of maximum permissible field strength at fixed radio monitoring station site is suggested. If the field strength of the radio stations situated near radio monitoring station does not exceed the calculated value, then they do not cause radio interferences to the radio monitoring station.
Keywords :
electromagnetic fields; radiofrequency interference; radiofrequency measurement; fixed radio monitoring station; maximum permissible field strength; radio interference; strong electromagnetic fields; Bandwidth; Electromagnetic compatibility; Equations; Mathematical model; Monitoring; Noise; Receivers; calculation of maximum permissible field strength; fixed radio monitoring station; harmful radio interference; intermodulation products;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility (EMC Europe), 2014 International Symposium on
Conference_Location :
Gothenburg
Type :
conf
DOI :
10.1109/EMCEurope.2014.6931065
Filename :
6931065
Link To Document :
بازگشت