DocumentCode :
1281980
Title :
Fast Charge to Pulse Width Converter for Monolith PET Detector
Author :
Parl, C. ; Larue, H. ; Streun, M. ; Ziemons, K. ; Van Waasen, S.
Author_Institution :
Zentralinst. fur Elektron., Forschungszentrum Julich GmbH, Julich, Germany
Volume :
59
Issue :
5
fYear :
2012
Firstpage :
1809
Lastpage :
1814
Abstract :
Currently both preclinical and clinical PET systems are built with pixilated, optically isolated scintillators. The use of optical isolators limits the achievable packing fraction for designs that use small crystals. No optical isolation is necessary in a monolithic scintillation crystal design hence the sensitivity is increased. The light distribution created by a high energy interaction in a monolithic scintillator can be readout by a SiPM-array to determine the 3-D position of the interaction. We have developed a digital pulse width modulation readout circuit that is able to readout many densely packed SiPM-arrays connected to monolithic scintillators. A monolithic scintillation detector requires simultaneous acquisition of the light distribution on multiple sensors unlike in a one-to-one optically isolated pixelated configuration. Therefore, pulse width modulation can reduce the readout complexity of the monolithic scintillation detector. The circuit gives an output signal with a pulse width linear to the incoming charge. Therefore, the circuit provides both timing and intensity information using just one digital line per channel. The charge to pulse-width conversion ratio of the circuit is adjustable (e.g., 33 ns/pC). The trigger jitters σ 41.2 ps between two channels. The PCB offers 8 channels and comes with additional features: The gain variation of a SiPM is compensated over a large temperature range by controlling the bias voltage. We measured from 15°C to 42°C, here it can bring the variation of a SiPM in gain from -21 ns/ °C to +3.8 ns/ °C or stabilizes the variation of the energy resolution between 18 and 20%.
Keywords :
nuclear electronics; photomultipliers; positron emission tomography; pulse width modulation; silicon radiation detectors; solid scintillation detectors; 3-D position determination; bias voltage control; charge-to-pulse-width conversion ratio; clinical PET systems; densely packed SiPM-arrays; digital pulse width modulation readout circuit; energy resolution; high energy interaction; light distribution; monolith PET detector; monolithic scintillation crystal design; monolithic scintillation detector; optically isolated pixelated conήguration; pixilated optically isolated scintillator detector; preclinical PET systems; pulse width converter; temperature 15 degC to 42 degC; trigger jitter system; Detectors; Energy resolution; Optical detectors; Optical imaging; Optical pulses; Temperature measurement; Analog circuits; medical imaging; scintillation detectors;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2012.2209128
Filename :
6296736
Link To Document :