DocumentCode
1284323
Title
Double-line-to-neutral short circuit of an alternator
Author
Smith, James B. ; Weygandt, Cornelius N.
Author_Institution
Associated Factory Mutual Fire Insurance Companies, Boston, Mass.
Volume
56
Issue
9
fYear
1937
Firstpage
1149
Lastpage
1155
Abstract
Starting with R. H. Park´s formulas for the flux linkages of an ideal synchronous machine, the case of a fault from 2 line terminals of a generator to neutral is treated in a manner similar to that used by Doherty and Nickle for other unsymmetrical faults. Expressions are given for the armature currents in the faulted phases and for the main field current, at any time after the short circuit. An expression for the voltage across the open phase a short time after the fault is also developed.
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1937.6538992
Filename
6538992
Link To Document