DocumentCode
1285607
Title
Diagnostics of insulation deterioration of ethylene propylene rubber using an acoustic emission technique
Author
Sakoda, Tatsuya ; Nakashima, Toshihiko ; Nainggolan, Jannus Maurits ; Otsubo, Masahisa ; Kurihara, Satoshi ; Nagasato, Shinya ; Yarimitsu, Takayoshi
Author_Institution
Dept. of Electr. & Electron. Eng., Univ. of Miyazaki, Miyazaki, Japan
Volume
17
Issue
4
fYear
2010
fDate
8/1/2010 12:00:00 AM
Firstpage
1242
Lastpage
1248
Abstract
The aim of this study is to investigate the relationship between lowering of the insulation performance of ethylene propylene rubber (EPR) used as a covering material of a cross-linked polyethylene (XLPE) cable and partial discharges (PDs) and to establish a diagnostic technique using an acoustic emission (AE) sensor. An accelerated deterioration test was carried out and then the detected AE signals were evaluated. The results showed that not only the intensity of the AE signal but also the number of counted AE signals of more than a critical value was very useful for diagnosing the EPR. We also proposed a diagnostic sequence using an AE technique.
Keywords
Acoustic emission, Fault diagnosis, Insulator testing, Power cable testing; Acoustic emission; Acoustic materials; Acoustic sensors; Acoustic testing; Attenuation; Cable insulation; Electrodes; Insulation; Joints; Life estimation; Materials; Paramagnetic resonance; Partial discharges; Polyethylene; Power cables; Rubber;
fLanguage
English
Journal_Title
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
1070-9878
Type
jour
DOI
10.1109/TDEI.2010.5539696
Filename
5539696
Link To Document