DocumentCode :
1285607
Title :
Diagnostics of insulation deterioration of ethylene propylene rubber using an acoustic emission technique
Author :
Sakoda, Tatsuya ; Nakashima, Toshihiko ; Nainggolan, Jannus Maurits ; Otsubo, Masahisa ; Kurihara, Satoshi ; Nagasato, Shinya ; Yarimitsu, Takayoshi
Author_Institution :
Dept. of Electr. & Electron. Eng., Univ. of Miyazaki, Miyazaki, Japan
Volume :
17
Issue :
4
fYear :
2010
fDate :
8/1/2010 12:00:00 AM
Firstpage :
1242
Lastpage :
1248
Abstract :
The aim of this study is to investigate the relationship between lowering of the insulation performance of ethylene propylene rubber (EPR) used as a covering material of a cross-linked polyethylene (XLPE) cable and partial discharges (PDs) and to establish a diagnostic technique using an acoustic emission (AE) sensor. An accelerated deterioration test was carried out and then the detected AE signals were evaluated. The results showed that not only the intensity of the AE signal but also the number of counted AE signals of more than a critical value was very useful for diagnosing the EPR. We also proposed a diagnostic sequence using an AE technique.
Keywords :
Acoustic emission, Fault diagnosis, Insulator testing, Power cable testing; Acoustic emission; Acoustic materials; Acoustic sensors; Acoustic testing; Attenuation; Cable insulation; Electrodes; Insulation; Joints; Life estimation; Materials; Paramagnetic resonance; Partial discharges; Polyethylene; Power cables; Rubber;
fLanguage :
English
Journal_Title :
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
1070-9878
Type :
jour
DOI :
10.1109/TDEI.2010.5539696
Filename :
5539696
Link To Document :
بازگشت