Conducting screen utilisation in switched reluctance motors
Author
Dessouky, Y.G. ; Williams, B.W. ; Fletcher, J.E.
Author_Institution
Dept. of Control & Electr. Eng., Arab Acad. for Sci. & Technol., Alexandria, Egypt
Volume
14
Issue
4
fYear
1999
fDate
12/1/1999 12:00:00 AM
Firstpage
946
Lastpage
951
Abstract
In this paper, the effect of incorporating nonmagnetic electrical conducting screens in the motor topology of a switched reluctance motor is investigated. It is shown that screens on the rotor increase the motor torque by reducing the effective unaligned AC inductance due to the eddy currents induced in the screens. Screens added to the end laminations on both the rotor and stator stacks are shown to minimise the end flux leakage. Details of experimental and analytical methods used to evaluate the effects of conducting screens are provided and test results on a 500 W motor are included
Keywords
eddy currents; inductance; laminations; magnetic flux; magnetic leakage; reluctance motors; rotors; shielding; stators; torque; 500 W; conducting screen; eddy currents; end flux leakage minimisation; end laminations; motor torque increase; nonmagnetic electrical conducting screens; rotor screens; stator stacks; switched reluctance motors; unaligned AC inductance reduction; AC motors; Eddy currents; Inductance; Induction motors; Lamination; Reluctance motors; Rotors; Stators; Topology; Torque;