Title :
Stray-load losses of D-C machines
Author :
Schilling, E.W. ; Koopman, R.W.
Author_Institution :
Michigan College of Mining and Technology, Houghton
Abstract :
This article describes a method of measuring stray-load losses which is readily adaptable to the test departments of the manufacturers. Usually no additional test apparatus will be required beyond that already available. The same arrangement used for a pump-back heat-run test is used with only slight modification. Experimental data are given showing the effect of speed, load, and field strength upon these losses.
Journal_Title :
Electrical Engineering
DOI :
10.1109/EE.1937.6539362