DocumentCode :
1286640
Title :
Methods of stator winding on-line diagnostics for large turbine generator preventive maintenance
Author :
Poljakov, V. ; Tsvetkov, V.
Author_Institution :
VNIIE, Electr. Power Res. Inst., Moscow, Russia
Volume :
14
Issue :
4
fYear :
1999
fDate :
12/1/1999 12:00:00 AM
Firstpage :
1646
Lastpage :
1650
Abstract :
The introduction of on-line diagnostic methods is a mandatory condition for the transition from the existing maintenance system to a preventive maintenance system. This paper analyses the methods of early detection of the most common defects in stator windings of large turbine generators with water cooling. The detection of overheating and leaks in the winding is described. The examples are given in which the detection of these defects and their repair prevented failures with heavy consequences
Keywords :
cooling; fault location; leak detection; maintenance engineering; stators; temperature measurement; turbogenerators; leak detection; overheating detection; stator winding on-line diagnostics; turbine generator preventive maintenance; water cooling; Bars; Cooling; Leak detection; Measurement standards; Power generation; Preventive maintenance; Stator windings; Temperature measurement; Temperature sensors; Turbines;
fLanguage :
English
Journal_Title :
Energy Conversion, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8969
Type :
jour
DOI :
10.1109/60.815118
Filename :
815118
Link To Document :
بازگشت