DocumentCode
1286901
Title
Control center for electronic automatic exchange
Author
Wedmore, W.R.
Author_Institution
Automatic Electric Laboratories, Inc., Northlake, Ill.
Volume
83
Issue
74
fYear
1964
Firstpage
453
Lastpage
458
Abstract
MAINTENANCE PERSONNEL in an electromechanical telephone office, particularly the direct-controlled type, are generally able to see what is going on and to diagnose any troubles that may develop by using standard test apparatus. Of course, this is not possible in an electronic telephone exchange, and it is necessary that the equipment itself pinpoint each fault as far as possible and describe it in terms that will assure proper action by the maintenance personnel.