• DocumentCode
    1287383
  • Title

    Evaluation of a Warm-Thermistor Flow Sensor for Use in Automatic Seepage Meters

  • Author

    Skinner, Andrew J. ; Lambert, Martin F.

  • Author_Institution
    Meas. Eng. Australia, Magill, SA, Australia
  • Volume
    9
  • Issue
    9
  • fYear
    2009
  • Firstpage
    1058
  • Lastpage
    1067
  • Abstract
    A warm-thermistor flow sensor is evaluated for use in an automatic seepage meter measuring very slow groundwater inflows into open water bodies. A novel control circuit allows a single self-referencing thermistor to operate with a constant heat output of 36.8 mW, while monitoring the thermistor´s internal temperature TS and TF under still-water and flow conditions respectively. The resultant temperature difference TS-TF is the output signal from the instrument. This device is particularly sensitive to very slow fluid flows in the range 0.03 to 3 mm/s, where buoyancy problems have traditionally prevented the use of warm-thermistor flow meters. For flow speeds below 3 mm/s the sensor response was shown in the laboratory to be nearly linear with no offset term. Two flow-calibration setups were investigated; a precision plunging-probe apparatus and a single-step flow calibration system based upon a Hagen-Poiseuille flow regulator and a vertical standpipe. A numerical (CFD) model of the spherical thermistor agreed well with the two experimental calibration procedures over the flow range between 0 and 3 mm/s. The theoretical model - based on the Peclet number - fits the CFD model well between 3 and 100 mm/s, but does not hold true in the buoyancy range below 3 mm/s. For a seepage meter funnel having a bell-to-throat area ratio of 2964, groundwater flow velocities as low as 0.01 mum/s (0.9 mm/day) could be measured using this sensor.
  • Keywords
    Poiseuille flow; computational fluid dynamics; flow measurement; flow sensors; pipe flow; thermistors; Hagen-Poiseuille flow regulator; Peclet number; automatic seepage meters; buoyancy problems; computational fluid dynamics; flow calibration; groundwater flow velocities; inflow measurement; open water bodies; slow groundwater; spherical thermistor; vertical standpipe; warm thermistor flow sensor; Automatic control; Calibration; Circuits; Computational fluid dynamics; Condition monitoring; Fluid flow measurement; Instruments; Temperature control; Temperature sensors; Thermistors; Buoyancy; seepage meter; slow flow; warm-thermistor flow meter;
  • fLanguage
    English
  • Journal_Title
    Sensors Journal, IEEE
  • Publisher
    ieee
  • ISSN
    1530-437X
  • Type

    jour

  • DOI
    10.1109/JSEN.2009.2024056
  • Filename
    5191279